Compatible APC rack-ear cable comb — 3D print spec
When a small polymer rack-ear cable-comb clip on APC equipment fractures or goes obsolete as a standalone spare, additive manufacturing reproduces the functional clip from your own STL file without scrapping a working assembly. Below are the exact polymer selection data (PETG vs ABS, and why PLA is unsuitable), dimensional tolerances and deterministic mesh checks used before fulfilment.
Independent fabrication from your supplied CAD/STL file — not affiliated with or endorsed by APC. Need a complete factory-moulded assembly instead? Source genuine used OEM stock.
Additive specification sheet
apc-rack-ear-cable-comb-clip.stl
- Primary polymer
- PETG (1.27 g/cm³)
- Minimum reliable wall
- ≥ 1.2 mm (proxy ~4.89 mm)
- Typical bounding envelope
- 88 × 44 × 38 mm
- Nominal solid volume / mass
- ~50.0 cm³ · ~39.4 g
- Fitment & clearance target
- +0.30 mm on 6.5 mm M6 rack screw slots; smooth chamfered cable throats
- Unsuitable polymer
- PLA (softens ~55 °c)
- Indicative guide (non-binding)
- £18 – £45 · Typically 5–8 working days
Non-affiliation, safety & IP gate
Three boundaries checked before printing.
Every 3D spare-part quote request checks model licence, safety-category suitability and bureau availability before we send a firm written price.
Not affiliated with APC
MeWeBe Limited (PreviewFix) is an independent fabrication broker and is not affiliated with, authorised by or endorsed by APC. Brand and model references identify compatibility dimensions only. You supply an .STL file that you created or hold under CC0, CC BY or CC BY-SA; NonCommercial (NC) and NoDerivatives (ND) files are refused automatically.
Part-specific & safety limits
Boundary for this part: Low-voltage structured-cabling management comb on 19-inch rails only — keep clear of switch cooling intakes.
- Automotive braking, steering, suspension, wheel hubs, airbags, seatbelt pretensioners or structural crash members.
- Mains-voltage electrical enclosures, live terminal housings, battery-cell contacts or uncertified flame-retardant barriers.
- Gas valves, burners, flues, pressurised water or steam lines, boiler seals or heated internal oven cavities.
- Direct food-contact or potable-water surfaces (layer-printed plastics harbour micro-crevices unless food-safe coated and certified).
- Structural overhead load-bearing brackets, lifting gear, blade guards, riving knives, medical devices or firearm components.
Indicative guide & firm email quote
Indicative guide £18 – £45 (non-binding) — no online payment is taken here. Send your part details (and reply to our confirmation email with any supporting documents, photos, STL/CAD or PDF files); our UK team confirms printability, partner bureau availability, lead time and a firm written price before you decide whether to proceed.
Polymer & process engineering
Material selection for this rack-ear.
Operating environment: 25–55 °C 19-inch comms enclosure, static weight of 12–24 Cat6/Cat6A patch leads.
| Suitability role | Polymer & process | Density | Min wall | Build structure | Engineering rationale |
|---|---|---|---|---|---|
| Primary recommendation | PETG FDM · Service to ~70 °C | 1.27 g/cm³ | 1.2 mm | FDM · 4 perimeter walls + 40% gyroid infill | Organises Cat6/Cat6A patch bundles cleanly beside 19-inch cage-nut rails while tolerating warm comms-cabinet air up to ~70 °C without sagging. |
| Viable alternative | ABS FDM · Service to ~95 °C | 1.04 g/cm³ | 1.2 mm | Enclosed FDM · 4 perimeter walls + 45% cubic infill | Extra thermal headroom (~95 °C) for dense server/PoE switch cabinets with elevated hot-aisle temperatures. |
| Unsuitable — avoid | PLA FDM · Softens ~55 °C | 1.24 g/cm³ | 1.2 mm | FDM · Not recommended | Closed comms closets running PoE+ switches commonly reach 45–55 °C, where cantilevered PLA cable combs creep downward under patch-cord weight. |
APC platform & moulding notes
Identifying your revision before printing
- Equipment architecture
- NetShelter SX/SV 19-inch server enclosures, Smart-UPS rack/tower fascias and Rack PDU vertical/horizontal power strips.
- Catalogue & rating-plate lookup
AR8xxx/APxxxxaccessory code or internal870-xxxxbezel latch part number.- Original cavity polymer stamp
- NetShelter blanking panels, cable combs and Smart-UPS bezel latches carry
>ABS<or>PC-ABS<stamps.
Smart-UPS plastic front-bezel latches frequently snap during routine lead-acid battery cartridge swaps, leaving the fascia hanging loose.
Fitment & layer orientation
Vernier-calliper verification checklist
M6 cage-nut flange bracket & slotted finger comb · +0.30 mm on 6.5 mm M6 rack screw slots; smooth chamfered cable throats
Print flat on the comb profile so every cable-finger cantilever consists of continuous XY perimeter loops.
- Measure outer jacket diameter of your Cat6 (
~6.0 mm) or shielded Cat6A (~7.5 mm) patch leads. - Verify EIA-310 1U hole spacing (
15.88 mm—15.88 mm—12.70 mmvertical pattern) on mounting ears. - Chamfer all inner edges to ≥ 1.0 mm radius so cable jackets never chafe.
Deterministic printability engine
Six mesh checks verified before printing.
Before confirming a firm written price and dispatching to a partner bureau, our mesh engine parses your binary or ASCII STL in millimetres and runs six geometric checks.
| Engine check | Pass / warn threshold | What this catches on a rack-ear cable-comb clip |
|---|---|---|
| Closed (watertight) manifold meshcheck:watertight | 0 boundary edges · 0 non-manifold edges · consistent outward face normals | Every triangle edge on your rack-ear cable-comb clip STL must be shared by two faces traversed in opposite directions so the slicer resolves internal vs external shell walls cleanly. |
| Zero-area / degenerate trianglescheck:degenerate | 0 collapsed triangles (or < 1% warning threshold) | CAD fillet intersections around small snap-hooks and countersunk bosses often export zero-area slivers; heal or re-tessellate in CAD before uploading. |
| Millimetre unit & ×25.4 inch-scale checkcheck:units | Assumed mm · < 10 units flagged as likely inches (×25.4) · < 1 unit flagged as metres | Typical envelope is 88 × 44 × 38 mm. If exported in inches without unit metadata, raw coordinates read ~3.46 units max — our preview flags this before payment. |
| Minimum wall thickness (≥ 1.2 mm for PETG)check:wall | Overall min dimension ≥ 1.2 mm · 2V/A thickness proxy (~4.89 mm nominal) | Keep snap-arms, ribs and retention barbs at or above 1.2 mm (1.8 mm+ recommended at high-stress root fillets). |
| Printer build-envelope fit (FDM)check:build-volume | 2 mm axis margin · fits 9 profiled FDM machine(s) | Fits all 9 profiled FDM build volumes (Bambu Lab A1 mini, Bambu Lab A1, Bambu Lab P1S / X1C, Prusa MK4S, Prusa CORE One, Prusa XL, Creality Ender-3 V3, Creality K1 Max, Voron 2.4 (350)). |
| 45° overhang & support-scar checkcheck:overhang | Surface > 45° from vertical (> 5% area triggers supports) | Print flat on the comb profile so every cable-finger cantilever consists of continuous XY perimeter loops. |
Compatible FDM machine envelopes for 88 × 44 × 38 mm (+2 mm margin)
- Bambu Lab A1 mini180×180×180 mm
- Bambu Lab A1256×256×256 mm
- Bambu Lab P1S / X1C256×256×256 mm
- Prusa MK4S250×210×220 mm
- Prusa CORE One250×220×270 mm
- Prusa XL360×360×360 mm
- Creality Ender-3 V3220×220×250 mm
- Creality K1 Max300×300×300 mm
- Voron 2.4 (350)350×350×340 mm
Commercial reproduction rights
Permitted vs refused licences.
If you download a community-designed replacement clip rather than modelling your own CAD, our licence check verifies whether commercial bureau printing is allowed.
| Model licence | Gate decision | Delivery-note attribution | Rule applied |
|---|---|---|---|
| Original CAD / Buyer-owned | Allowed | Not required | Geometry modelled in-house or owned outright by your organisation; commercial printing permitted. |
| CC0-1.0 | Allowed | Not required | Public-domain dedication; commercial reproduction permitted without attribution. |
| CC-BY (1.0–4.0) | Allowed | Required (author + URL) | Commercial reproduction permitted when creator name, model title and deed URL are supplied for the delivery note. |
| CC-BY-SA (1.0–4.0) | Allowed | Required (author + URL) | Commercial reproduction permitted with creator attribution; any modified CAD file must remain under CC BY-SA. |
| CC-BY-NC / CC-BY-NC-SA / CC-BY-NC-ND | Refused | — | Refused automatically — NonCommercial terms prohibit paid print fulfilment without separate creator permission. |
| CC-BY-ND & platform-exclusive | Refused | — | Refused automatically — scaling, mesh repair or slicing can constitute an adaptation under NoDerivatives terms. |
Questions
Frequently asked questions.
Is this APC rack-ear cable-comb clip an official OEM spare part?
Why is PETG recommended over PLA for this part?
How do I verify my STL file matches my specific APC model revision?
Can I upload a model marked Creative Commons Non-Commercial (CC BY-NC)?
Related non-safety specifications
More APC & office & comms racks parts.
Same equipment brand · APC
Other printable APC parts
Same sector · Office & comms racks
Sibling equipment specifications
Request a quote · No online payment
Have an STL ready for quoting?
Send your part details for an indicative guide (£18 – £45, non-binding). No payment is taken online — we confirm printability, lead time and a firm written price by email, or you can request an OEM salvage quote for a complete factory assembly.