Skip to content
PreviewFix
Nylon PA12 (SLS) · SLSNon-safety polymer partAvoid PLA

Compatible Eaton PDU cord saddle clip — 3D print spec

When a small polymer pdu cord-retention saddle clip on Eaton equipment fractures or goes obsolete as a standalone spare, additive manufacturing reproduces the functional clip from your own STL file without scrapping a working assembly. Below are the exact polymer selection data (Nylon PA12 (SLS) vs ABS, and why PLA is unsuitable), dimensional tolerances and deterministic mesh checks used before fulfilment.

Independent fabrication from your supplied CAD/STL file — not affiliated with or endorsed by Eaton. Need a complete factory-moulded assembly instead? Source genuine used OEM stock.

Additive specification sheet

eaton-pdu-cord-retention-saddle-clip.stl

SLS verified
Primary polymer
Nylon PA12 (SLS) (1.01 g/cm³)
Minimum reliable wall
≥ 0.8 mm (proxy ~3.27 mm)
Typical bounding envelope
46 × 32 × 22 mm
Nominal solid volume / mass
~12.0 cm³ · ~12.1 g
Fitment & clearance target
+0.10 mm on metal tray slot; snug cradle behind moulded IEC plug shoulder
Unsuitable polymer
PLA (softens ~55 °c)
Indicative guide (non-binding)
£18 – £45 · Typically 5–8 working days
No online payment taken — we confirm printability, lead time and a firm price by emailBy quote

Non-affiliation, safety & IP gate

Three boundaries checked before printing.

Every 3D spare-part quote request checks model licence, safety-category suitability and bureau availability before we send a firm written price.

01 · Trade mark & file ownershipIndependent

Not affiliated with Eaton

MeWeBe Limited (PreviewFix) is an independent fabrication broker and is not affiliated with, authorised by or endorsed by Eaton. Brand and model references identify compatibility dimensions only. You supply an .STL file that you created or hold under CC0, CC BY or CC BY-SA; NonCommercial (NC) and NoDerivatives (ND) files are refused automatically.

Need an original factory-moulded Eaton assembly instead? Use OEM Salvage Finder (indicative £120 – £300, by quote).
02 · Non-safety scopeStrict exclusion

Part-specific & safety limits

Boundary for this part: External mechanical strain-relief saddle on the mounting bracket only — never insert printed plastics into live IEC socket apertures or internal PDU housings.

  • Automotive braking, steering, suspension, wheel hubs, airbags, seatbelt pretensioners or structural crash members.
  • Mains-voltage electrical enclosures, live terminal housings, battery-cell contacts or uncertified flame-retardant barriers.
  • Gas valves, burners, flues, pressurised water or steam lines, boiler seals or heated internal oven cavities.
  • Direct food-contact or potable-water surfaces (layer-printed plastics harbour micro-crevices unless food-safe coated and certified).
  • Structural overhead load-bearing brackets, lifting gear, blade guards, riving knives, medical devices or firearm components.
03 · Request a quoteNo online payment

Indicative guide & firm email quote

Indicative guide £18 – £45 (non-binding) — no online payment is taken here. Send your part details (and reply to our confirmation email with any supporting documents, photos, STL/CAD or PDF files); our UK team confirms printability, partner bureau availability, lead time and a firm written price before you decide whether to proceed.

Polymer & process engineering

Material selection for this PDU cord.

Operating environment: 35–65 °C rear rack hot-aisle exhaust and downward weight of heavy 1.0–1.5 mm² IEC power cords.

Suitability rolePolymer & processDensityMin wallBuild structureEngineering rationale
Primary recommendation

Nylon PA12 (SLS)

SLS · Service to ~100 °C

1.01 g/cm³0.8 mmSolid sintered cross-section (100% coalesced PA12)High-toughness nylon (~100 °C service ceiling) snaps onto the external metal retention tray/ear beside rack PDU outlets to stop heavy IEC C13/C19 leads vibrating loose.
Viable alternative

ABS

FDM · Service to ~95 °C

1.04 g/cm³1.2 mmEnclosed FDM · 4 perimeter walls + 50% cubic infillThermal stability up to ~95 °C in rear hot-aisle zero-U vertical PDU channels.
Unsuitable — avoid

PLA

FDM · Softens ~55 °C

1.24 g/cm³1.2 mmFDM · Not recommendedRear server exhaust air blows directly onto zero-U PDU brackets at 50–65 °C, softening PLA clips immediately.

Eaton platform & moulding notes

Identifying your revision before printing

Equipment architecture
5P, 5PX and 9PX rack/tower UPS front bezels, ePDU G3 rack power strips (external cord retention saddles) and IT rack enclosures.
Catalogue & rating-plate lookup
744-xxxxx bezel/kit number or EBABxx / EBAxxx rack airflow & cable-management accessory reference.
Original cavity polymer stamp
Rack airflow blanks and cord-retention clips use >ABS< and >PA66<.

External mechanical PDU cord-retention clips engage only the insulated PVC outer cord jacket on the chassis bracket — never live IEC socket contacts.

Fitment & layer orientation

Vernier-calliper verification checklist

External tray snap-saddle gripping insulated cord neck · +0.10 mm on metal tray slot; snug cradle behind moulded IEC plug shoulder

SLS PA12 recommended for thin tray-barbs; on enclosed ABS print flat across the U-saddle profile.

  • Measure slotted steel retention-bar width and thickness running alongside the PDU chassis.
  • Measure stand-off distance from the bar to the back shoulder of your moulded IEC C13/C19 plug.
  • Confirm clip contacts only the external earthed metal bracket and outer PVC cord overmould.

Deterministic printability engine

Six mesh checks verified before printing.

Before confirming a firm written price and dispatching to a partner bureau, our mesh engine parses your binary or ASCII STL in millimetres and runs six geometric checks.

Engine checkPass / warn thresholdWhat this catches on a pdu cord-retention saddle clip
Closed (watertight) manifold meshcheck:watertight0 boundary edges · 0 non-manifold edges · consistent outward face normalsEvery triangle edge on your pdu cord-retention saddle clip STL must be shared by two faces traversed in opposite directions so the slicer resolves internal vs external shell walls cleanly.
Zero-area / degenerate trianglescheck:degenerate0 collapsed triangles (or < 1% warning threshold)CAD fillet intersections around small snap-hooks and countersunk bosses often export zero-area slivers; heal or re-tessellate in CAD before uploading.
Millimetre unit & ×25.4 inch-scale checkcheck:unitsAssumed mm · < 10 units flagged as likely inches (×25.4) · < 1 unit flagged as metresTypical envelope is 46 × 32 × 22 mm. If exported in inches without unit metadata, raw coordinates read ~1.81 units max — our preview flags this before payment.
Minimum wall thickness (≥ 0.8 mm for Nylon PA12 (SLS))check:wallOverall min dimension ≥ 0.8 mm · 2V/A thickness proxy (~3.27 mm nominal)Keep snap-arms, ribs and retention barbs at or above 0.8 mm (1.4 mm+ recommended at high-stress root fillets).
Printer build-envelope fit (SLS)check:build-volume2 mm axis margin · fits 1 profiled SLS machine(s)Fits all 1 profiled SLS build volumes (Formlabs Fuse 1+).
45° overhang & support-scar checkcheck:overhangSLS powder bed self-supports overhangs (supportsLikely: false)SLS PA12 recommended for thin tray-barbs; on enclosed ABS print flat across the U-saddle profile.

Compatible SLS machine envelopes for 46 × 32 × 22 mm (+2 mm margin)

  • Formlabs Fuse 1+165×165×300 mm

Commercial reproduction rights

Permitted vs refused licences.

If you download a community-designed replacement clip rather than modelling your own CAD, our licence check verifies whether commercial bureau printing is allowed.

Model licenceGate decisionDelivery-note attributionRule applied
Original CAD / Buyer-ownedAllowedNot requiredGeometry modelled in-house or owned outright by your organisation; commercial printing permitted.
CC0-1.0AllowedNot requiredPublic-domain dedication; commercial reproduction permitted without attribution.
CC-BY (1.0–4.0)AllowedRequired (author + URL)Commercial reproduction permitted when creator name, model title and deed URL are supplied for the delivery note.
CC-BY-SA (1.0–4.0)AllowedRequired (author + URL)Commercial reproduction permitted with creator attribution; any modified CAD file must remain under CC BY-SA.
CC-BY-NC / CC-BY-NC-SA / CC-BY-NC-NDRefused—Refused automatically — NonCommercial terms prohibit paid print fulfilment without separate creator permission.
CC-BY-ND & platform-exclusiveRefused—Refused automatically — scaling, mesh repair or slicing can constitute an adaptation under NoDerivatives terms.

Questions

Frequently asked questions.

Is this Eaton pdu cord-retention saddle clip an official OEM spare part?
No. This is an independent, on-demand additive manufacturing service and is not affiliated with, authorised by or endorsed by Eaton. You upload a 3D mesh file (.STL) that you designed yourself or hold under a commercial-permissive licence (CC0, CC BY or CC BY-SA). If you need a genuine factory-moulded assembly instead, use our OEM Salvage Part Landed-Cost Broker.
Why is Nylon PA12 (SLS) recommended over PLA for this part?
High-toughness nylon (~100 °C service ceiling) snaps onto the external metal retention tray/ear beside rack PDU outlets to stop heavy IEC C13/C19 leads vibrating loose. Conversely, Rear server exhaust air blows directly onto zero-U PDU brackets at 50–65 °C, softening PLA clips immediately.
How do I verify my STL file matches my specific Eaton model revision?
Check the appliance or vehicle code (744-xxxxx bezel/kit number or EBABxx / EBAxxx rack airflow & cable-management accessory reference.) and compare your broken clip with vernier callipers against the bounding box in our free preview (typical envelope around 46 × 32 × 22 mm) before paying.
Can I upload a model marked Creative Commons Non-Commercial (CC BY-NC)?
No. Our automated licence gate allows buyer-owned CAD, CC0-1.0, CC BY and CC BY-SA (printing creator attribution on the delivery note where required). Files carrying NonCommercial (NC), NoDerivatives (ND) or restrictive repository licences are refused automatically.

Related non-safety specifications

More Eaton & office & comms racks parts.

Request a quote · No online payment

Have an STL ready for quoting?

Send your part details for an indicative guide (£18 – £45, non-binding). No payment is taken online — we confirm printability, lead time and a firm written price by email, or you can request an OEM salvage quote for a complete factory assembly.