Compatible Vax tube parking clip — 3D print spec
When a small polymer extension tube storage parking clip on Vax equipment fractures or goes obsolete as a standalone spare, additive manufacturing reproduces the functional clip from your own STL file without scrapping a working assembly. Below are the exact polymer selection data (PETG vs Nylon PA12 (SLS), and why Standard resin (SLA/MSLA) is unsuitable), dimensional tolerances and deterministic mesh checks used before fulfilment.
Independent fabrication from your supplied CAD/STL file — not affiliated with or endorsed by Vax. Need a complete factory-moulded assembly instead? Source genuine used OEM stock.
Additive specification sheet
vax-extension-tube-storage-parking-clip.stl
- Primary polymer
- PETG (1.27 g/cm³)
- Minimum reliable wall
- ≥ 1.2 mm (proxy ~4.45 mm)
- Typical bounding envelope
- 54 × 38 × 30 mm
- Nominal solid volume / mass
- ~24.6 cm³ · ~19.4 g
- Fitment & clearance target
- +0.15 mm clearance in rear tub parking pocket
- Unsuitable polymer
- Standard resin (SLA/MSLA) (service to ~55 °c)
- Indicative guide (non-binding)
- £18 – £45 · Typically 5–8 working days
Non-affiliation, safety & IP gate
Three boundaries checked before printing.
Every 3D spare-part quote request checks model licence, safety-category suitability and bureau availability before we send a firm written price.
Not affiliated with Vax
MeWeBe Limited (PreviewFix) is an independent fabrication broker and is not affiliated with, authorised by or endorsed by Vax. Brand and model references identify compatibility dimensions only. You supply an .STL file that you created or hold under CC0, CC BY or CC BY-SA; NonCommercial (NC) and NoDerivatives (ND) files are refused automatically.
Part-specific & safety limits
Boundary for this part: Passive storage parking clip on the outer vacuum body only.
- Automotive braking, steering, suspension, wheel hubs, airbags, seatbelt pretensioners or structural crash members.
- Mains-voltage electrical enclosures, live terminal housings, battery-cell contacts or uncertified flame-retardant barriers.
- Gas valves, burners, flues, pressurised water or steam lines, boiler seals or heated internal oven cavities.
- Direct food-contact or potable-water surfaces (layer-printed plastics harbour micro-crevices unless food-safe coated and certified).
- Structural overhead load-bearing brackets, lifting gear, blade guards, riving knives, medical devices or firearm components.
Indicative guide & firm email quote
Indicative guide £18 – £45 (non-binding) — no online payment is taken here. Send your part details (and reply to our confirmation email with any supporting documents, photos, STL/CAD or PDF files); our UK team confirms printability, partner bureau availability, lead time and a firm written price before you decide whether to proceed.
Polymer & process engineering
Material selection for this tube parking.
Operating environment: Cantilevered bending moment from parked steel extension tube and transit vibration.
| Suitability role | Polymer & process | Density | Min wall | Build structure | Engineering rationale |
|---|---|---|---|---|---|
| Primary recommendation | PETG FDM · Service to ~70 °C | 1.27 g/cm³ | 1.2 mm | FDM · 4 perimeter walls + 45% gyroid infill | High flexural toughness holds heavy stainless steel extension wands upright in the rear tub slot during cupboard storage and van transit. |
| Viable alternative | Nylon PA12 (SLS) SLS · Service to ~100 °C | 1.01 g/cm³ | 0.8 mm | Solid sintered cross-section (100% coalesced PA12) | Preferred for commercial fleet tub vacs where steel wands are slammed into the rear parking slot. |
| Unsuitable — avoid | Standard resin (SLA/MSLA) SLA · Service to ~55 °C | 1.15 g/cm³ | 0.6 mm | SLA · Not recommended | Cantilevered wand leverage cracks brittle resin parking tongues immediately. |
Vax platform & moulding notes
Identifying your revision before printing
- Equipment architecture
- BLADE / ONEPWR cordless stick vacuums, Air Stretch corded uprights and Mach Air cylinder cleaners.
- Catalogue & rating-plate lookup
1-1-xxxxxx-00hyphenated Vax spare part number matched to theU8.../CLSV-...model code.- Original cavity polymer stamp
- Dirt-bin tabs, filter latches and wall-mount clips use
>ABS<or>PP<.
Exhaust filter grille latches and dirt-canister baffle tabs on older Air and Mach cylinder ranges frequently become unavailable long before motor failure.
Fitment & layer orientation
Vernier-calliper verification checklist
Slide-in parking hook / C-saddle · +0.15 mm clearance in rear tub parking pocket
Orient side-on so the cantilevered hook arm has uninterrupted perimeter fibres around the root bend.
- Measure rear tub slot width, depth and draft taper in millimetres.
- Measure collared ring diameter on the stainless or aluminium extension tube.
- Check root fillet radius for maximum bending strength.
Deterministic printability engine
Six mesh checks verified before printing.
Before confirming a firm written price and dispatching to a partner bureau, our mesh engine parses your binary or ASCII STL in millimetres and runs six geometric checks.
| Engine check | Pass / warn threshold | What this catches on a extension tube storage parking clip |
|---|---|---|
| Closed (watertight) manifold meshcheck:watertight | 0 boundary edges · 0 non-manifold edges · consistent outward face normals | Every triangle edge on your extension tube storage parking clip STL must be shared by two faces traversed in opposite directions so the slicer resolves internal vs external shell walls cleanly. |
| Zero-area / degenerate trianglescheck:degenerate | 0 collapsed triangles (or < 1% warning threshold) | CAD fillet intersections around small snap-hooks and countersunk bosses often export zero-area slivers; heal or re-tessellate in CAD before uploading. |
| Millimetre unit & ×25.4 inch-scale checkcheck:units | Assumed mm · < 10 units flagged as likely inches (×25.4) · < 1 unit flagged as metres | Typical envelope is 54 × 38 × 30 mm. If exported in inches without unit metadata, raw coordinates read ~2.13 units max — our preview flags this before payment. |
| Minimum wall thickness (≥ 1.2 mm for PETG)check:wall | Overall min dimension ≥ 1.2 mm · 2V/A thickness proxy (~4.45 mm nominal) | Keep snap-arms, ribs and retention barbs at or above 1.2 mm (1.8 mm+ recommended at high-stress root fillets). |
| Printer build-envelope fit (FDM)check:build-volume | 2 mm axis margin · fits 9 profiled FDM machine(s) | Fits all 9 profiled FDM build volumes (Bambu Lab A1 mini, Bambu Lab A1, Bambu Lab P1S / X1C, Prusa MK4S, Prusa CORE One, Prusa XL, Creality Ender-3 V3, Creality K1 Max, Voron 2.4 (350)). |
| 45° overhang & support-scar checkcheck:overhang | Surface > 45° from vertical (> 5% area triggers supports) | Orient side-on so the cantilevered hook arm has uninterrupted perimeter fibres around the root bend. |
Compatible FDM machine envelopes for 54 × 38 × 30 mm (+2 mm margin)
- Bambu Lab A1 mini180×180×180 mm
- Bambu Lab A1256×256×256 mm
- Bambu Lab P1S / X1C256×256×256 mm
- Prusa MK4S250×210×220 mm
- Prusa CORE One250×220×270 mm
- Prusa XL360×360×360 mm
- Creality Ender-3 V3220×220×250 mm
- Creality K1 Max300×300×300 mm
- Voron 2.4 (350)350×350×340 mm
Commercial reproduction rights
Permitted vs refused licences.
If you download a community-designed replacement clip rather than modelling your own CAD, our licence check verifies whether commercial bureau printing is allowed.
| Model licence | Gate decision | Delivery-note attribution | Rule applied |
|---|---|---|---|
| Original CAD / Buyer-owned | Allowed | Not required | Geometry modelled in-house or owned outright by your organisation; commercial printing permitted. |
| CC0-1.0 | Allowed | Not required | Public-domain dedication; commercial reproduction permitted without attribution. |
| CC-BY (1.0–4.0) | Allowed | Required (author + URL) | Commercial reproduction permitted when creator name, model title and deed URL are supplied for the delivery note. |
| CC-BY-SA (1.0–4.0) | Allowed | Required (author + URL) | Commercial reproduction permitted with creator attribution; any modified CAD file must remain under CC BY-SA. |
| CC-BY-NC / CC-BY-NC-SA / CC-BY-NC-ND | Refused | — | Refused automatically — NonCommercial terms prohibit paid print fulfilment without separate creator permission. |
| CC-BY-ND & platform-exclusive | Refused | — | Refused automatically — scaling, mesh repair or slicing can constitute an adaptation under NoDerivatives terms. |
Questions
Frequently asked questions.
Is this Vax extension tube storage parking clip an official OEM spare part?
Why is PETG recommended over Standard resin (SLA/MSLA) for this part?
How do I verify my STL file matches my specific Vax model revision?
Can I upload a model marked Creative Commons Non-Commercial (CC BY-NC)?
Related non-safety specifications
More Vax & floorcare parts.
Same equipment brand · Vax
Other printable Vax parts
Same sector · Floorcare
Sibling equipment specifications
Request a quote · No online payment
Have an STL ready for quoting?
Send your part details for an indicative guide (£18 – £45, non-binding). No payment is taken online — we confirm printability, lead time and a firm written price by email, or you can request an OEM salvage quote for a complete factory assembly.